Skip to Content
AED / Defibrillator · Complete Indoor Bundle

Philips HeartStart HS1
Indoor Bundle

SKU: M5066A_C02_BI · Everything installed and ready from day one · Made in USA
Bundle Price €1,395.00 0% VAT · Finance Act 2023
10-Year Total €2,150.50 all consumable replacements included
Per Day (10yr) 59c less than a cup of coffee
Best for: Offices · Schools · Hotels · Nursing homes · Pharmacies · Shopping centres · Gyms & fitness centres
Philips HeartStart HS1 Indoor Bundle
Emergency response
Why every workplace needs a defibrillator
Survival falls 10% with every minute without defibrillation.
The HS1 delivers a shock in ~8 seconds — meeting the ERC, AHA, and RC(UK) guideline for CPR pause under 10 seconds.
Section01
Key Features & Specifications
Quick Shock Time
~8 sec
CPR pause under 10 seconds. Fewer than 4 AEDs in the world meet the ERC/AHA/RC(UK) 2015 guideline. No fully automated AED qualifies.
First-Shock Efficacy · AHA Class IIa
96%
SMART Biphasic technology — AHA "standard of care." Backed by 40+ peer-reviewed studies (Schneider et al, Circulation 2000).
Units Sold Worldwide
2 million+
At least 4x more than any other manufacturer (PwC, June 2016). Only OTC-approved AED by the US FDA.
AED ModelPhilips HeartStart HS1 (M5066A)
TechnologySMART Biphasic — AHA Class IIa "standard of care" · 40+ peer-reviewed studies
Energy & Current Delivered150J · 21.0A — more current than most AEDs at 200J (current is the clinically relevant measure: AHA, ERC)
Shock Time (CPR pause)~8 seconds (Quick Shock) — one of fewer than 4 AEDs in the world meeting this standard
Guidance SystemVoice-guided, step by step — no medical knowledge required
Adult Pads (M5071A)Pre-installed · for patients 8+ years / 25kg+ · 2 years and 2 months standby life after installation
Battery (M5070A)Lithium · 4-year standby after insertion · Install Before date printed on battery label
Country of OriginUSA
IndemnificationVoid if expired or non-Philips consumables used — grace period ended June 2023
Clinical Context — Why Current Beats Joules

Best chance of survival is a shock within 3-5 minutes of collapse (Scott 2017, Myat 2018). Current — not energy in joules — is the physiologically relevant measure (AHA, ERC). At 150J the HS1 delivers 21.0A; a competitor at 200J delivers only 18.5A. The HS1's SMART Biphasic waveform adapts to each patient's impedance in real time to maximise efficacy.

Section02
Bundle Contents — Everything Included at €1,395
Complete From Day One

Every item you need for a compliant, ready-to-use AED installation is in the box. No additional purchases required to go live.

M5066A_C02_BI — €1,395 · 0% VAT · 6 items included
Philips HeartStart HS1 AED M5066A
SMART Biphasic · Quick Shock ~8 sec · voice-guided · with slim carry case (C02 variant M5076A)
Adult SMART Pads Cartridge M5071A
Pre-installed in AED · for patients 8+ years / 25kg+ · 2yr 2mo standby life · 0% VAT
Lithium Battery M5070A
4-year standby after insertion · Install Before date on label · 0% VAT
Arky Wall-Mounted Metal Cabinet
Indoor alarmed cabinet · audible alarm on opening · 0% VAT
CPR Rescue BLS Pack 5001049G
Face shield · gloves · razor · wipes · scissors — everything needed for CPR alongside defibrillation
AED Location Signage
Wall signage directing staff and responders to the AED location
Section03
Running Costs — 10-Year Total Ownership
YearEventItemCost
Year 0Initial purchaseHS1 Indoor Bundle M5066A_C02_BI
AED + pads + battery + case + cabinet + CPR pack + signage
€1,395.00
Year 2Pad replacementAdult SMART Pads M5071A€79.50
Year 4Battery + padsBattery M5070A (€179.00) + Pads M5071A (€79.50)€258.50
Year 6Pad replacementAdult SMART Pads M5071A€79.50
Year 8Battery + padsBattery M5070A (€179.00) + Pads M5071A (€79.50)€258.50
Year 10Pad replacementAdult SMART Pads M5071A€79.50
10-Year Total Cost of Ownership€2,150.50

All consumable prices 0% VAT (Finance Act 2023). Battery M5070A: €179.00 · Adult pads M5071A: €79.50. Prices from hayesfirstaid.com — subject to change.

AED Guardian Service — Free Consumable Expiry Reminders
Register your AED with Hayes First Aid and we monitor your pad and battery expiry dates automatically — three reminders per expiry event.
90 daysFirst reminder — time to plan your replacement order
60 daysSecond reminder — confirm order is placed
30 daysFinal reminder — replacement should already be on hand
FREE service · included with all AED purchases from Hayes First Aid · register at hayesfirstaid.com
Section04
Routine Maintenance — The HS1 Monitors Itself
Minimal Maintenance. Maximum Reliability.

The Philips HeartStart HS1 runs automatic self-tests every day, week, and month. It monitors battery capacity, pads readiness, and internal circuitry without any action from you. Your only job is to keep consumables in date — and our AED Guardian Service handles the reminders.

Automated Self-Tests

The HS1 automatically tests itself daily, weekly, and monthly. Tests cover battery capacity, pads cartridge readiness, shock delivery circuitry, and all internal systems.

Green light blinking = AED is ready for use
If the AED Alerts You
Single chirpPress the blue i-button. The AED will voice-prompt the issue. Call Hayes First Aid if in doubt.
Triple chirpPotentially serious. Call Hayes First Aid immediately in standby mode. During emergency: press blue i-button, follow voice prompts.
After Deployment — 5-Step Protocol

If the AED has been used on a patient:

  1. 1Check outside of AED for damage, dirt, or contamination
  2. 2Replace pads: locate latch at top edge, slide to side, lift out used cartridge, insert new — click into place, green PULL handle fully down
  3. 3Check all supplies and accessories for damage and expiry dates; replace anything used, damaged, or expired
  4. 4Remove battery for 10 seconds, then reinstall to run battery insertion self-test (BIT)
  5. 5AED auto self-tests on reinsertion; press button when instructed; AED returns to standby
Disposal of Used Consumables

Used pads cartridges and batteries are hazardous waste — not general rubbish. Do not put in your bin or send to landfill (illegal under S.I. 283/2014).

Where to bring them (free)

Local authority civic amenity site · Any retailer selling the same battery type · Blue Battery Boxes (supermarkets, newsagents)

HFA Take-Back Service

Ask about our take-back service when ordering replacement consumables. sales@hayesfirstaid.com

Section05
Paediatric Use — Under 8 Years / Under 25kg
Child Pads SKUM5072A
Price€145.00 · 0% VAT
Patient criteriaAge <8 years AND weight <25kg
Pad standby life2 years from manufacture date
In the bundle?No — sold separately
Recommended For

Schools, creches, sports clubs, community halls, and any setting where children are regularly present. The HS1 adult pads are approved for patients 8+ years / 25kg+. Child pads take precedence when available.

Section06
Regulatory Compliance & Registration

EU Medical Device Regulation (MDR 2017/745)

The HS1 is a Class IIb active medical device. Supplied with UDI label — do not cover or remove. CE marked. Manufactured in the USA.

HPRA Registration & Named Responsible Person

Hayes First Aid is registered with the HPRA as a medical device distributor (S.I. 691/2021 / EU MDR Chapter III). HPRA requires a named responsible person for your AED and registration with your local distributor — we manage this on your behalf. hpra.ie

NAS Registration — National AED Network

Register your AED with the National Ambulance Service (NAS) National AED Network so emergency dispatchers can direct bystanders to your device when calling 112 / 999. An estimated 9,000 AEDs are in Ireland — fewer than half are registered. An unregistered AED cannot be dispatched. Registration is free. becomeacfr.ie/aed · Register online

Consumable Integrity & Philips Indemnification

Philips indemnification is void if expired or non-Philips consumables are used. The grace period ended June 2023. Our AED Guardian Service (90/60/30-day reminders) ensures you are never caught with expired consumables.

Zero VAT — All Bundle Items

AED units, adult pads, batteries, and cabinets are zero-rated under the Finance Act 2023 (Revenue TDM, September 2025). No VAT to claim back. Child pads M5072A also 0% VAT.

Section07
Why Hayes First Aid
2013
Keeping Ireland rescue-ready since 2013
HPRA
Registered medical device distributor
0%
VAT on all AED equipment — nothing to reclaim
Free
90/60/30-day expiry reminders, for life
Authorised Philips Distributor — Irish Market

Hayes First Aid is an authorised distributor of Philips HeartStart AEDs in Ireland. All units are supplied new, with full manufacturer warranty and Irish-market documentation. Post-deployment event data can be reviewed and analysed by our team using Philips Event Review Pro software — ask about this service when you register your AED.

Websitehayesfirstaid.com
Emailsales@hayesfirstaid.com
Phone069 66006 / 01 5079900
EircodeV42 N220
VAT No.IE9737609O
Trading entityMacroMed Healthcare Limited, t/a Hayes First Aid

Prices correct July 2026 · Subject to change · All items 0% VAT (Finance Act 2023) · Sources: Philips manufacturer documentation, AED360-ProCardio partner training May 2025, Revenue.ie TDM Sept 2025, HPRA.ie, becomeacfr.ie · Hayes First Aid