Skip to Content
Next working day delivery to all 32 countiesFree delivery over €100 ex VAT069 66006 · Mon–Fri 09:00–17:00 (GMT)PricesInc VATEx VATContact
Hayes First Aid
Saved0Basket0 Sign inSign inAlready buy from us?Get your loginNew customer?Start hereBusiness or organisation?Get your pricingNo account needed to order.
0
Next working day delivery to all 32 countiesFree delivery over €100 ex VAT
AED / Defibrillator · Complete Indoor Bundle

Philips HeartStart HS1
Indoor Bundle

SKU: M5066A_C02_BI · Everything installed and ready from day one · Made in USA
Bundle Price €1,395.00 0% VAT · Finance Act 2023
10-Year Total €2,150.50 all consumable replacements included
Per Day (10yr) 59c less than a cup of coffee
Best for: Offices · Schools · Hotels · Nursing homes · Pharmacies · Shopping centres · Gyms & fitness centres
Philips HeartStart HS1 Indoor Bundle
Emergency response
Why every workplace needs a defibrillator
Survival falls 10% with every minute without defibrillation.
The HS1 delivers a shock in ~8 seconds — meeting the ERC, AHA, and RC(UK) guideline for CPR pause under 10 seconds.
Section01
Key Features & Specifications
Quick Shock Time
~8 sec
CPR pause under 10 seconds. Fewer than 4 AEDs in the world meet the ERC/AHA/RC(UK) 2015 guideline. No fully automated AED qualifies.
First-Shock Efficacy · AHA Class IIa
96%
SMART Biphasic technology — AHA "standard of care." Backed by 40+ peer-reviewed studies (Schneider et al, Circulation 2000).
Units Sold Worldwide
2 million+
At least 4x more than any other manufacturer (PwC, June 2016). Only OTC-approved AED by the US FDA.
AED ModelPhilips HeartStart HS1 (M5066A)
TechnologySMART Biphasic — AHA Class IIa "standard of care" · 40+ peer-reviewed studies
Energy & Current Delivered150J · 21.0A — more current than most AEDs at 200J (current is the clinically relevant measure: AHA, ERC)
Shock Time (CPR pause)~8 seconds (Quick Shock) — one of fewer than 4 AEDs in the world meeting this standard
Guidance SystemVoice-guided, step by step — no medical knowledge required
Adult Pads (M5071A)Pre-installed · for patients 8+ years / 25kg+ · 2 years and 2 months standby life after installation
Battery (M5070A)Lithium · 4-year standby after insertion · Install Before date printed on battery label
Child Pads (M5072A)For patients <8 years / <25 kg · 2 years · sold separately · €145 · 0% VAT
Country of OriginUSA
IndemnificationVoid if expired or non-Philips consumables used — grace period ended June 2023
Clinical Context — Why Current Beats Joules

Best chance of survival is a shock within 3-5 minutes of collapse (Scott 2017, Myat 2018). Current — not energy in joules — is the physiologically relevant measure (AHA, ERC). At 150J the HS1 delivers 21.0A; a competitor at 200J delivers only 18.5A. The HS1's SMART Biphasic waveform adapts to each patient's impedance in real time to maximise efficacy.

Section02
Bundle Contents — Everything Included at €1,395
Complete From Day One

Every item you need for a compliant, ready-to-use AED installation is in the box. No additional purchases required to go live.

M5066A_C02_BI — €1,395 · 0% VAT · 6 items included
Philips HeartStart HS1 AED M5066A
SMART Biphasic · Quick Shock ~8 sec · voice-guided · with slim carry case (C02 variant M5076A)
Adult SMART Pads Cartridge M5071A
Pre-installed in AED · for patients 8+ years / 25kg+ · 2yr 2mo standby life · 0% VAT
Lithium Battery M5070A
4-year standby after insertion · Install Before date on label · 0% VAT
Arky Wall-Mounted Metal Cabinet
Indoor alarmed cabinet · audible alarm on opening · 0% VAT
CPR Rescue BLS Pack 5001049G
Face shield · gloves · razor · wipes · scissors — everything needed for CPR alongside defibrillation
AED Location Signage
Wall signage directing staff and responders to the AED location
Section03
Running Costs — 10-Year Total Ownership
YearEventItemCost
Year 0Initial purchaseHS1 Indoor Bundle M5066A_C02_BI
AED + pads + battery + case + cabinet + CPR pack + signage
€1,395.00
Year 2Pad replacementAdult SMART Pads M5071A€79.50
Year 4Battery + padsBattery M5070A (€179.00) + Pads M5071A (€79.50)€258.50
Year 6Pad replacementAdult SMART Pads M5071A€79.50
Year 8Battery + padsBattery M5070A (€179.00) + Pads M5071A (€79.50)€258.50
Year 10Pad replacementAdult SMART Pads M5071A€79.50
10-Year Total Cost of Ownership€2,150.50

All consumable prices 0% VAT (Finance Act 2023). Battery M5070A: €179.00 · Adult pads M5071A: €79.50. Prices from hayesfirstaid.com — subject to change.

AED Guardian Service — Free Consumable Expiry Reminders
Register your AED with Hayes First Aid and we monitor your pad and battery expiry dates automatically — three reminders per expiry event.
90 daysFirst reminder — time to plan your replacement order
60 daysSecond reminder — confirm order is placed
30 daysFinal reminder — replacement should already be on hand
FREE service · included with all AED purchases from Hayes First Aid · register at hayesfirstaid.com
Section04
Routine Maintenance — The HS1 Monitors Itself
Minimal Maintenance. Maximum Reliability.

The Philips HeartStart HS1 runs automatic self-tests every day, week, and month. It monitors battery capacity, pads readiness, and internal circuitry without any action from you. Your only job is to keep consumables in date — and our AED Guardian Service handles the reminders.

Automated Self-Tests

The HS1 automatically tests itself daily, weekly, and monthly. Tests cover battery capacity, pads cartridge readiness, shock delivery circuitry, and all internal systems.

Green light blinking = AED is ready for use
If the AED Alerts You
Single chirpPress the blue i-button. The AED will voice-prompt the issue. Call Hayes First Aid if in doubt.
Triple chirpPotentially serious. Call Hayes First Aid immediately in standby mode. During emergency: press blue i-button, follow voice prompts.
After Deployment — 5-Step Protocol

If the AED has been used on a patient:

  1. 1Check outside of AED for damage, dirt, or contamination
  2. 2Replace pads: locate latch at top edge, slide to side, lift out used cartridge, insert new — click into place, green PULL handle fully down
  3. 3Check all supplies and accessories for damage and expiry dates; replace anything used, damaged, or expired
  4. 4Remove battery for 10 seconds, then reinstall to run battery insertion self-test (BIT)
  5. 5AED auto self-tests on reinsertion; press button when instructed; AED returns to standby
Disposal of Used Consumables

Used pads cartridges and batteries are hazardous waste — not general rubbish. Do not put in your bin or send to landfill (illegal under S.I. 283/2014).

Where to bring them (free)

Local authority civic amenity site · Any retailer selling the same battery type · Blue Battery Boxes (supermarkets, newsagents)

HFA Take-Back Service

Ask about our take-back service when ordering replacement consumables. sales@hayesfirstaid.com

Section05
Paediatric Use — Under 8 Years / Under 25kg
Child Pads SKUM5072A
Price€145.00 · 0% VAT
Patient criteriaAge <8 years AND weight <25kg
Pad standby life2 years from manufacture date
In the bundle?No — sold separately
Recommended For

Schools, creches, sports clubs, community halls, and any setting where children are regularly present. The HS1 adult pads are approved for patients 8+ years / 25kg+. Child pads take precedence when available.

Section06
Regulatory Compliance & Registration

EU Medical Device Regulation (MDR 2017/745)

The HS1 is a Class IIb active medical device. Supplied with UDI label — do not cover or remove. CE marked. Manufactured in the USA.

HPRA Registration & Named Responsible Person

Hayes First Aid is registered with the HPRA as a medical device distributor (S.I. 691/2021 / EU MDR Chapter III). HPRA requires a named responsible person for your AED and registration with your local distributor — we manage this on your behalf. hpra.ie

NAS Registration — National AED Network

Register your AED with the National Ambulance Service (NAS) National AED Network so emergency dispatchers can direct bystanders to your device when calling 112 / 999. An estimated 9,000 AEDs are in Ireland — fewer than half are registered. An unregistered AED cannot be dispatched. Registration is free. becomeacfr.ie/aed · Register online

Consumable Integrity & Philips Indemnification

Philips indemnification is void if expired or non-Philips consumables are used. The grace period ended June 2023. Our AED Guardian Service (90/60/30-day reminders) ensures you are never caught with expired consumables.

Zero VAT — All Bundle Items

AED units, adult pads, batteries, and cabinets are zero-rated under the Finance Act 2023 (Revenue TDM, September 2025). No VAT to claim back. Child pads M5072A also 0% VAT.

Section07
Why Hayes First Aid
2013
Keeping Ireland rescue-ready since 2013
HPRA
Registered medical device distributor
0%
VAT on all AED equipment — nothing to reclaim
Free
90/60/30-day expiry reminders, for life
Authorised Philips Distributor — Irish Market

Hayes First Aid is an authorised distributor of Philips HeartStart AEDs in Ireland. All units are supplied new, with full manufacturer warranty and Irish-market documentation. Post-deployment event data can be reviewed and analysed by our team using Philips Event Review Pro software — ask about this service when you register your AED.

Websitehayesfirstaid.com
Emailsales@hayesfirstaid.com
Phone069 66006 / 01 5079900
EircodeV42 N220
VAT No.IE9737609O
Trading entityMacroMed Healthcare Limited, t/a Hayes First Aid

Prices correct July 2026 · Subject to change · All items 0% VAT (Finance Act 2023) · Sources: Philips manufacturer documentation, AED360-ProCardio partner training May 2025, Revenue.ie TDM Sept 2025, HPRA.ie, becomeacfr.ie · Hayes First Aid

A family-run Irish business supplying defibrillators, first aid and rescue equipment, and the training and servicing that go with them. Founded 2012.

MacroMed Healthcare Limited
trading as Hayes First Aid
Castle Demesne, Newcastle West, Co. Limerick, V42 N220
069 66006 · Mon–Fri 09:00–17:00 (GMT)
Follow us for safety notices and new products
Shop
Help
Company
© 2026 MacroMed Healthcare Limited, t/a Hayes First Aid. Registered in Ireland, CRN 510559. VAT IE9824728C. WEEE retailer take-back Reg. No. 20208. In an emergency call 112/999. Irish workplace first aid: S.I. No. 299 of 2007. Card and account payments accepted.